Leave Your Message

OCPP EV Charger for Charging Network Operators

Engineered for high uptime, active load balancing, seamless OCPP 2.0.1/1.6J compliance, and robust European grid regulations.

99.8%
Field Uptime Target
< 100ms
Load Balancing Response
100%
OCPP Profile Interop
48-Hr
EU/UK Critical Spares SLA
Engineering Integrity

Addressing the Real-World OCPP Interoperability Gap

Why procurement teams across the EU, UK, and Nordics face operational bottlenecks after deploying chargers marketed as "OCPP Compliant".

Operational Dimension Market Pitfalls ("Paper-Only" OCPP) HizonSun Enterprise Standard CPO Bottom-Line Impact
Protocol Conformance Superficial Support Partial OCPP 1.6J implementation; missing Smart Charging profiles, non-standard key-value configurations, broken TLS encryption. Complete Stack Full OCPP 1.6J and native ocpp 2.0 ev charger core profiles including secure WebSocket connection, certificate management, and transaction queues. Zero CPMS platform lock-in, effortless onboarding with major EU backends (GreenFlux, AMPECO, Driivz, Monta).
Dynamic Load Balancing (DLB) Local Hub Failure Simple unmanaged loops or cloud-only throttles that drop offline whenever WAN connectivity suffers jitter. Sub-Second Hardware Grid Dual-layer Dynamic Load Balancing (Local master/slave + Cloud OCPP Smart Charging Profiles 1.6/2.0.1) operating reliably offline or online. Avoids grid breaker trips, maximizes charging capacity under strict EU distribution grid constraints without infrastructure upgrades.
Remote Firmware & Maintenance High Roll-Out Risk Aborted FOTA updates lock hardware flash memory ("bricked" units), requiring on-site engineer truck rolls. Fail-Safe A/B Dual Partition Remote firmware update EV charger system with automatic fallback rollback if image verification or handshake fails. Reduces operational OPEX truck rolls by over 80%; prevents multi-week station outage states.
Hardware Resilience & Spare Parts Long Lead Times Proprietary monolithic power stacks; 8-16 weeks lead time for replacement modules; no localized European safety inventory. Modular Redundancy Hot-swappable power modules, standardized contactors, pre-stocked European hubs for rapid replacement. Mitigates the true cost of downtime (lost revenue, SLA financial penalties, and degraded public reviews).
Grid-Optimized Architecture

Multi-Charger Dynamic Load Balancing for EV Charging Networks

In public fast charging deployments across Germany, the UK, the Netherlands, and the Nordic territory, grid substation connection upgrades represent the highest single capital expenditure barrier. Our integrated load balancing ev charging station ecosystem guarantees precise power management across multiple vehicle charging bays.

Whether utilizing local Ethernet daisy-chaining, Modbus RS-485 metering, or OCPP SetChargingProfile commands, the cluster adjusts real-time current allocation dynamically per vehicle's Battery Management System (BMS) requirement, grid limiters, and time-of-use tariffs.

  • Active Phase Balancing: Mitigates single-phase residential/commercial load imbalances in European 400V 3-phase grids.
  • Local Substation Integration: Interfaces seamlessly with external RTUs and energy management systems via Modbus TCP/IP.
  • Failsafe Offline Fallback: Automatic fallback current capping prevents tripping site main circuit breakers even under complete broadband loss.
Schedule OCPP Integration Test

Multi-Point Dynamic Cluster Architecture

Central Substation / GridHizonSun Master GatewayLocal Balancing Core & OCPP 2.0.1High-Power DC PileDynamic: 180 kWSplit-Type DC PileDynamic: 120 kWAC Commercial PileDynamic: 22 kWSub-second dynamic reallocation responding to individual EV charging curves
Turnkey Scalability

EV Charger Bulk Supply for Charging Network Deployments

Providing high-tier CPOs and turn-key contractors with stable manufacturing throughput, customizable hardware white-labeling, and verified component durability.

EU & UK Compliance

CE, MID (Measuring Instruments Directive) compliant metering, Eichrecht certified readiness for German markets, and compliance with the UK Public Charge Point Regulations 2023.

ISO 15118 & Plug & Charge

Embedded hardware security modules (HSM) ready for ISO 15118-2 and ISO 15118-20, enabling automated Plug & Charge authentication without reliance on RFID or third-party phone apps.

Guaranteed Spare Parts

Strategic stock keeping of silicon-carbide (SiC) modules, liquid-cooled dispensers, mainboards, and contactors maintained for CPO contractual 5-year and 10-year service lifecycles.

Extreme Nordic Weather

Engineered for Nordic climate criteria (-35°C to +55°C), equipped with smart internal condensation heating, IP54/IP55 ingress sealing, and IK10 impact protection casings.

Core Product Portfolios

Standard Hardware Offerings for Network Expansion

Seamlessly integrate our standard AC and 大功率直流桩 into your CPMS infrastructure with native OCPP compliance.

AC EV Charger for Commercial Public Stations

Commercial AC EV Charger

7kW - 22kW intelligent charging pillar with RFID, POS terminal integration, and dual-socket capability for municipal curbside and workplace hubs.

View Technical Data
Integrated DC Fast Charger for Public Hubs

Integrated DC Fast Charger

60kW - 240kW all-in-one charging station with dual CCS2 connectors, intelligent power distribution, and 96% power efficiency conversion.

View Technical Data
Split-Type DC Fast EV Charging Station

Split-Type DC Charging Matrix

360kW - 720kW centralized power matrix with multi-dispenser architecture, liquid-cooled ultra-fast cables, and dynamic cross-bay power sharing.

View Technical Data
Energy Storage Integrated DC Charging System

BESS Integrated Charging Pile

100kWh - 200kWh battery energy storage coupled with DC fast charging, peak shaving for constrained European distribution grids.

View Technical Data
Software & Connectivity

Tested Interoperability with Leading Backends

Many EV charging station manufacturers state compliance on datasheets, yet integration engineers discover missing payload parameters, unhandled diagnostic messages, or unsupported WebSocket SSL handshakes during rollout.

Our firmware is pre-validated against standard test suites and leading commercial platforms. Explore our specialized OCPP 平台介绍页 to inspect detailed communication protocol logs, OCPP message payloads (BootNotification, Heartbeat, StatusNotification, Authorize, Start/StopTransaction, MeterValues), and customized vendor error-handling attributes.

✓ OCPP 1.6-JSON Certified
✓ Native OCPP 2.0.1 Ready
✓ ISO 15118 Security Profiles
// Real-time OCPP 1.6/2.0.1 Dynamic Profile Event
[2, "98234-hz-dlb", "SetChargingProfile", {
"connectorId": 1,
"csChargingProfiles": {
"chargingProfileId": 104,
"stackLevel": 1,
"chargingProfilePurpose": "TxDefaultProfile",
"chargingProfileKind": "Absolute",
"chargingSchedule": {
"duration": 3600,
"chargingRateUnit": "A",
"chargingSchedulePeriod": [
{"startPeriod": 0, "limit": 250.0, "numberPhases": 3}
]
}
}
}]
// Execution completed across cluster under 82ms
International Quality Verification

Certified for Demanding Global Deployments

Every charging station is manufactured under strict ISO9001/14001 guidelines and comprehensively tested to conform with IEC 61851-1, IEC 61851-23, and European safety standards.

Certification 1
Certification 2
Certification 3
Certification 4
Field Rollouts

Network Operator Case Studies & Global News

Demonstrating robust execution in high-power infrastructure rollouts worldwide.

HizonSun Brings 180kW DC Fast Chargers to Thailand

HizonSun Delivers 180kW DC Fast Chargers for Major Infrastructure Projects

Read Deployment Overview →
HizonSun Ships 20 Units of 160kW DC Fast Chargers

Bulk Supply of 160kW DC Fast Chargers for Regional Network Hubs

Read Deployment Overview →
HizonSun Manufacturing Excellence

Manufacturing Excellence: Powering Global Shift to Rapid High-Voltage Hubs

Read Deployment Overview →
European Standard CCS2 DC Fast Chargers

CCS2 Standard Bulk Deliveries for Multi-Operator Public Hubs

Read Deployment Overview →

Book an OCPP Interoperability & DLB Test

Validate OCPP 1.6J / OCPP 2.0.1 compatibility with your CPMS backend before placing bulk procurement orders. Our technical team supports complete live API, payload, and load-shedding diagnostics.